InverterWorks Request a quote
Menu

Residential solar inverters

Solar inverter for home: pick the right type and size

A home inverter decides how much of the array you can actually use, whether a battery can be added later, and what happens in a blackout. Here is how the four families differ, and how to size one from your loads instead of from the panel count.

  • Sized from loads, not panel count
  • Battery-ready vs battery-only
  • Backup and grid-code rules
DC IN MPPT DC TO AC 48V DC BUS AC OUT

DC array input · AC house output

Sizing

How to size a home inverter

Three decisions set the whole system: the load you must carry, the battery voltage you already own, and what happens when the grid goes down.

Current draw for 5,000 W, three battery voltages
12 V 24 V 48 V 417 A 208 A 104 A

Same load, thinner cable as voltage rises. Above roughly 3 kW, 48 V is the practical choice.

  1. 01

    List the loads you must carry

    Add up everything that runs at once, then add surge for pumps and compressors. The number you need is continuous kW plus the starting wattage of the largest motor.

  2. 02

    Fix the battery voltage

    12V for a cabin, 24V for a small system, 48V above roughly 3 kW. The bank voltage decides which inverter family you can even consider.

  3. 03

    Decide what happens in a blackout

    Grid-tie, hybrid or off-grid. This is a decision about the building, not about the inverter: it decides whether the unit has a grid input and a backup output.

Comparison

Inverter families compared for a home system

FamilyTypical household ratingBatteryWorks without a gridBest for
Grid tie1–10 kWNoneNoExport, lowest cost per watt
Hybrid3–12 kW48V (most models)With batterySelf-consumption plus backup
Off grid1–10 kW12/24/48VYesCabins, wells, full independence
Microinverter300–800 W per panelNoneNoShaded or mixed roofs
PV inverter1–20 kWHigh voltageNoString design and sizing

What a solar inverter does in a home system

It turns the direct current (DC) coming down from the panels into the 120/240 V alternating current (AC) the house uses. It also sets the rules for the whole system: it tracks each string's best operating point, synchronises with the grid, and decides where surplus energy goes.

The inverter is usually the first component to specify, because it fixes the battery voltage, the string length and whether backup is even possible.

The four families, and where each one fits

  • Grid tie string inverter — the cheapest way to turn roof area into kilowatt-hours. Modules are wired in series, commonly 200–500 V DC on a house; when the grid drops, the unit stops, because anti-islanding protection is a safety requirement.
  • Hybrid inverter — a grid tie inverter with a battery port and a changeover for backup loads. Residential sizes run about 3–12 kW on 48 V banks. One box shifts self-consumption today and adds backup or off-grid capacity later.
  • Off grid inverter — built for sites with no utility at all. Usually low frequency, with a transformer large enough to start motors at two to three times the continuous rating, on 12 V, 24 V or 48 V banks.
  • Microinverter — mounted under a single panel and converting that panel's DC on the spot. Shade and mixed roof orientations cost less, and there is no high-voltage DC on the roof, at a higher cost per watt.

Sizing: kilowatts, surge watts and volts

Size from the load you must carry, then from the array you want to connect.

  • Continuous rating: everything that runs at the same time. A fridge, a well pump, lights and a router add up faster than most people expect.
  • Surge: motors draw several times their rated current for a fraction of a second. A 1 kW pump can ask for 3 kW at start.
  • DC input window: the array voltage must sit inside the MPPT range across the whole year, not only at 25 °C on a bench.
  • Battery voltage: 12 V for a cabin, 24 V for a small system, 48 V above roughly 3 kW. No setting fixes a 24 V bank paired with a 48 V inverter.

On grid tie systems with a battery, a peak array of 1.2–1.4× the AC rating is normal. On off-grid systems the ratio is closer to 1:1, because extra panels only help if the battery can absorb the energy.

What actually moves the price

Housing, transformer size and surge rating move the price far more than the label on the box. Three other things do the same:

  • Export limit settings and anti-islanding certification for the local grid code.
  • Split-phase output for North American homes, which is a different product, not a setting.
  • Generator input, parallel capability, and whether the unit can be stacked for three phase later.

A 5 kW high-frequency hybrid and a 5 kW low-frequency off-grid inverter are not interchangeable, even when the two stickers look similar.

Five checks before you buy

Read the datasheet in this order:

  1. Continuous and surge output at the temperature the unit will actually live in.
  2. MPPT voltage window and start voltage.
  3. Battery chemistry, voltage band and communication protocol.
  4. Grid code certification for your country.
  5. Warranty terms, with a service address written down.

If a seller cannot answer the fourth point, the fifth rarely matters.

FAQ

Common questions

What size inverter do I need for a house?

Start with continuous load: add up everything that runs at the same time. Then check surge, because pumps and compressors draw two to three times their rating for a second. On grid-tie systems the inverter is usually sized near the array; on off-grid systems the battery capacity limits the array long before the inverter does.

Is a hybrid inverter the same as off-grid?

A modern hybrid inverter is an off-grid inverter plus a grid connection and export logic. Off-grid units are normally low-frequency with a larger transformer for motor starting, and many have no grid input at all. If the house has a utility connection and you want both, choose a hybrid.

Why is 48V used for most home inverters?

48V is the standard above roughly 3 kW because higher voltage means lower current and thinner cable. 12V and 24V still make sense in cabins and small systems where the loads are few. The battery bank and the inverter must share the same nominal voltage — this is the one mistake that cannot be fixed with settings.

Can a home inverter run during a blackout?

Yes on hybrid models with an AC output that keeps running when the grid drops. The backup output is often limited to a dedicated circuit panel rather than the whole house, so check the backup rating, the transfer time and whether the inverter can start your well pump.

Sourcing

Need the current datasheet?

Send the array size, battery voltage and the country the unit must be certified for. We reply with the matching models, datasheet and lead time.

Request a quote