What a solar inverter does in a home system
It turns the direct current (DC) coming down from the panels into the 120/240 V alternating current (AC) the house uses. It also sets the rules for the whole system: it tracks each string's best operating point, synchronises with the grid, and decides where surplus energy goes.
The inverter is usually the first component to specify, because it fixes the battery voltage, the string length and whether backup is even possible.
The four families, and where each one fits
- Grid tie string inverter — the cheapest way to turn roof area into kilowatt-hours. Modules are wired in series, commonly 200–500 V DC on a house; when the grid drops, the unit stops, because anti-islanding protection is a safety requirement.
- Hybrid inverter — a grid tie inverter with a battery port and a changeover for backup loads. Residential sizes run about 3–12 kW on 48 V banks. One box shifts self-consumption today and adds backup or off-grid capacity later.
- Off grid inverter — built for sites with no utility at all. Usually low frequency, with a transformer large enough to start motors at two to three times the continuous rating, on 12 V, 24 V or 48 V banks.
- Microinverter — mounted under a single panel and converting that panel's DC on the spot. Shade and mixed roof orientations cost less, and there is no high-voltage DC on the roof, at a higher cost per watt.
Sizing: kilowatts, surge watts and volts
Size from the load you must carry, then from the array you want to connect.
- Continuous rating: everything that runs at the same time. A fridge, a well pump, lights and a router add up faster than most people expect.
- Surge: motors draw several times their rated current for a fraction of a second. A 1 kW pump can ask for 3 kW at start.
- DC input window: the array voltage must sit inside the MPPT range across the whole year, not only at 25 °C on a bench.
- Battery voltage: 12 V for a cabin, 24 V for a small system, 48 V above roughly 3 kW. No setting fixes a 24 V bank paired with a 48 V inverter.
On grid tie systems with a battery, a peak array of 1.2–1.4× the AC rating is normal. On off-grid systems the ratio is closer to 1:1, because extra panels only help if the battery can absorb the energy.
What actually moves the price
Housing, transformer size and surge rating move the price far more than the label on the box. Three other things do the same:
- Export limit settings and anti-islanding certification for the local grid code.
- Split-phase output for North American homes, which is a different product, not a setting.
- Generator input, parallel capability, and whether the unit can be stacked for three phase later.
A 5 kW high-frequency hybrid and a 5 kW low-frequency off-grid inverter are not interchangeable, even when the two stickers look similar.
Five checks before you buy
Read the datasheet in this order:
- Continuous and surge output at the temperature the unit will actually live in.
- MPPT voltage window and start voltage.
- Battery chemistry, voltage band and communication protocol.
- Grid code certification for your country.
- Warranty terms, with a service address written down.
If a seller cannot answer the fourth point, the fifth rarely matters.