Off grid solar inverter: sizing, voltage and wiring

An off grid inverter has to start motors, refill the bank and keep running in a shed at 40 °C. Here is how to size one from surge watts and charger current instead of from a nameplate.

PV array 200–500 V DC Battery 48 V nominal House 120 / 230 V AC Grid or genset MPPT DC → AC Transfer relay 1 2 3 4 5

Anatomy

Five connections decide which model fits. Ask for the datasheet to confirm each one on the exact rating you are buying.

  1. 1PV DC inputString voltage window and max input current per tracker.
  2. 2MPPT trackerOne tracker per roof orientation; two trackers help a partly shaded array.
  3. 3Battery portNominal voltage and chemistry must match the bank you already own.
  4. 4AC outputContinuous and surge rating, and whether the backup panel is separate.
  5. 5Grid or genset inputGrid-code approval for your country, plus generator start support.

What off grid changes about the inverter

An off grid system has no utility to fall back on, so the inverter carries every load, every start and every mistake. That shifts the specification away from efficiency and toward surge capacity, charger current and idle draw. A unit that scores 97% on a datasheet but cannot start a 1 HP well pump is useless on a site with a pump.

Continuous and surge: the two numbers that matter

Continuous rating is what the inverter can supply indefinitely at the ambient temperature on site, which is often 40 °C in a shed, not 25 °C in a lab. Surge is the short-term overload that starts motors; a well pump or an air compressor can ask for two to three times its running watts for a few seconds.

A simple method:

  1. List every load and its running watts.
  2. Add the loads likely to run together — fridge, lights, router, well pump, tools.
  3. Add the starting watts of the largest motor once.
  4. Add 20–25% headroom for ageing batteries and hot days.

The result is the number to shop with, and it is nearly always larger than the kW on the sticker.

Battery voltage and charger current

The battery bank sets the DC voltage, and the voltage sets the current for a given power. At 3 kW, a 24 V bank carries about 125 A of DC current; a 48 V bank carries about 62 A. Lower current means thinner cable, smaller breakers and less heat, which is why 48 V is standard above roughly 3 kW and 12 V survives only in cabins.

Charger current matters as much as the inverter output in an off grid system: it determines how fast the array refills the bank after a cloudy day. Plan for a charger that can deliver roughly 10–20% of the bank's amp-hour capacity, and check the maximum PV input the unit accepts — a charger capped at 4 kW will clip a 6 kW array for much of the year.

Low frequency vs high frequency

Low-frequency units use a large iron transformer and weigh 20–40 kg or more. They tolerate surge, start motors and survive heat better, and they are the usual choice for pumps, workshops and full-time off grid houses. High-frequency units are lighter, cheaper and more efficient at part load, but their surge headroom is smaller.

Wiring basics

  • Cable size follows current and run length; a long DC run from the array costs more in copper than the difference between two inverter models.
  • Put a DC breaker between the battery bank and the inverter, rated for the continuous current plus a margin.
  • Ground the enclosure and the array frame to a single point, and bond the battery bank negative according to the local code.
  • Keep the inverter in a ventilated space; derating begins well before the case feels hot.

Matching the array to the bank

An off grid array only delivers what the battery can absorb. If the bank is 48 V 200 Ah (about 9.6 kWh nominal), an array much above 3–4 kW will spend the middle of sunny days at absorption voltage with nowhere to put the energy. Buy panels after you have sized the bank, not before.

When the site also has a grid connection or a generator that should charge the bank, a hybrid unit usually does the same job with a smaller parts count — see the hybrid and 48V guides.

FAQ

Common questions

How do I size an off grid inverter?

Add the running watts of everything that runs at once, then add the starting watts of the largest motor once. A 1 HP pump draws roughly 750 W running but can ask for 2–3 kW at start, so pumps, compressors and workshop tools usually set the size.

12V, 24V or 48V — which should I choose?

12 V suits a cabin with lights, a router and a small fridge. 24 V suits a mid-size cabin or a small house. 48 V is the practical choice above roughly 3 kW because it cuts DC current, cable size and heat. The battery bank and the inverter must share the same nominal voltage.

Should I buy a low frequency or high frequency off grid inverter?

Low frequency units carry a large transformer that survives motor starting and heat, at the cost of weight, idle draw and price. High frequency units are lighter, cheaper and more efficient at light load, but have less surge headroom. For pumps and full-time off grid houses, low frequency is the safer specification.

How much power does an off grid inverter waste at idle?

Expect 10–30 W of idle consumption on many low frequency units, which is 0.24–0.72 kWh a day. In a small system that is a real share of the budget, so check the figure on the datasheet and plan a standby or search mode if the inverter offers one.