PV inverter is a category, not a product
"PV inverter" describes the box that converts photovoltaic DC to AC; the term covers string inverters, hybrids, microinverters and central inverters. When a datasheet says PV inverter, the useful questions are which architecture it uses and what its DC input looks like: MPPT count, MPPT voltage window, maximum input current per tracker and maximum DC/AC ratio.
The four numbers that decide a design
- MPPT voltage window. The array must sit inside it at cell temperatures from −10 °C to 70 °C. Cold mornings push voltage up, hot roofs pull it down, and both ends have to clear.
- Maximum input current per MPPT. Modern 500–600 W modules produce more current than older strings were designed for. Two parallel strings on one tracker can exceed the limit even when the wattage looks fine.
- Max DC/AC ratio. 1.1–1.3 is normal in temperate climates; closer to 1.0 in hot, high-irradiance sites where clipping is expensive.
- Efficiency curve. The headline 97–98% is measured at a specific load. What matters at 10–20% load, where a residential array spends much of the morning, is the European or CEC weighted efficiency.
Strings, trackers and mismatch
A tracker serves one electrical environment. Panels on the same tracker should share orientation, tilt and shade profile. Adding a second orientation to the same tracker means the maximum power point moves between two groups all day, and the inverter finds a compromise that serves neither. Two MPPTs, or two units, solve it; a bigger single-tracker inverter does not.
Voltage check at the extremes
A worked example: 12 modules with 41 V open-circuit voltage at 25 °C, temperature coefficient −0.29%/°C. At −10 °C the string reaches roughly 41 × 12 × (1 + 35 × 0.0029) ≈ 542 V, which exceeds a 500 V maximum system voltage. The same string at 65 °C cell temperature drops toward 390 V. If the MPPT window ends at 425 V, both ends of the design are wrong — a 1000 V unit or a shorter string is the fix.
Single phase, three phase and where they meet
Residential PV inverters are mostly single phase up to about 10 kW. Above that, and on commercial rooftops, three phase units from 10–100 kW take over because balanced three phase output keeps phase imbalance within utility limits. The divide is a grid rule as much as a technical one: some utilities cap single phase export at 5 kW per phase regardless of what the inverter can do.
Hybrid or plain PV inverter
The decision is about batteries. A plain PV inverter is cheaper, lighter and has fewer failure points. A hybrid carries the battery port and backup changeover in the same box, which costs 10–30% more but avoids adding a second inverter later. If the customer is likely to add storage within three years, the hybrid is usually the cheaper total.
Buying for a project
For any project beyond a single house, ask for the datasheet plus the grid code certificate, the derating curve at 45 °C ambient, and the firmware change log. The first two decide whether the unit can be connected; the third tells you whether the model is still supported.