InverterWorks Request a quote

Panel-level conversion

Microinverter guide: ratings, wiring and monitoring

A microinverter converts each panel on the roof. It buys shade tolerance and no high-voltage DC, and it costs more per watt plus a gateway. Here is how to choose between it and a string inverter.

PV array 200–500 V DC Battery 48 V nominal House 120 / 230 V AC Grid or genset MPPT DC → AC Transfer relay 1 2 3 4 5

Anatomy

Five connections decide which model fits. Ask for the datasheet to confirm each one on the exact rating you are buying.

  1. 1PV DC inputString voltage window and max input current per tracker.
  2. 2MPPT trackerOne tracker per roof orientation; two trackers help a partly shaded array.
  3. 3Battery portNominal voltage and chemistry must match the bank you already own.
  4. 4AC outputContinuous and surge rating, and whether the backup panel is separate.
  5. 5Grid or genset inputGrid-code approval for your country, plus generator start support.

What a microinverter changes

A microinverter mounts under a single module and converts that module's DC to AC at the panel. Instead of one large inverter on a wall, a residential roof carries ten to thirty small units, each rated for one or two panels. The architecture changes four things: shade tolerance, roof wiring, monitoring and service.

Ratings: pick by panel, not by array

Microinverters are rated in watts of AC output, typically 300–800 W today, matching a single 350–600 W module or a pair of smaller ones. The pairing rule is to keep the module's STC power somewhat above the microinverter's continuous AC rating, so the unit runs near its peak for more of the day; the exact allowed ratio is set by the manufacturer's compatibility list, and installing outside it can void the warranty.

Check three numbers on the datasheet:

  • Continuous AC output and peak output.
  • Maximum input voltage and maximum input current — the second one is what rules out high-current modules.
  • Whether one unit accepts one module or two, since two-module units need matched panels.

Wiring and the trunk cable

The panels connect to a trunk cable that carries 240 V AC down to the service panel, so there is no high-voltage DC on the roof and no string calculations. Each branch has a maximum number of units per circuit — commonly around 10–15 on a 20 A branch — which is the practical limit on how large one array can be before you add another branch.

Monitoring needs a gateway

Most microinverter systems require the manufacturer's gateway or communications unit to report panel-level production. Without it you get energy but no diagnostics. The gateway also usually serves firmware updates, which matter because microinverters are not easy to reach once the roof is finished. Budget the gateway into the job, and confirm whether it needs a dedicated circuit.

When microinverters pay off

  • A roof with trees, chimneys or dormers, where shade moves across the array during the day.
  • Multiple roof planes facing different directions, without running separate strings.
  • Small arrays where a second MPPT on a string inverter costs more than the microinverter premium.
  • Installs where DC on the roof is unwelcome, such as some commercial or multifamily jobs.

They do not pay off on a large, unshaded, single-plane roof, where a string inverter is cheaper per watt and easier to replace at ground level.

Service and lifetime

A microinverter failure means getting on the roof, and often removing a module. That is why warranty terms and the service address matter more than the price difference between two brands. Ask for the expected replacement process and the warranty period in writing; ten to twenty-five years are both on the market today.

Buying for resale

If you are stocking microinverters for installers, the questions shift to compatibility: which modules are on the local market, which trunk cable lengths ship locally, and whether the gateway is certified for the country's grid code. A unit without a local grid code certificate cannot be commissioned, regardless of its rating.

FAQ

Common questions

How do I match a microinverter to a panel?

Match each microinverter to one or two modules from the manufacturer's compatibility list. Module STC power usually sits somewhat above the unit's continuous AC output, and the maximum input current on the datasheet is the number that rules out high-current modules.

Can microinverters provide power in a blackout?

No. Microinverters convert per module and shut down with the grid like any grid tie unit, so they cannot supply backup. If backup is required, the system needs a battery inverter or a hybrid inverter with a backup output.

Do I need a gateway to use microinverters?

Usually yes for production data, no for firmware and diagnostics. Most brands require their gateway or communications unit for panel-level monitoring, and some warranty terms assume monitoring is installed. Check what the gateway needs — power, network and sometimes a dedicated circuit.

Are microinverters worth the extra cost?

Roughly, a roof with one clean plane is better served by a string inverter, and a roof with shade, several orientations or a small array is better served by microinverters. The break-even usually appears when optimisers or a second MPPT would be added to the string design anyway.

Sourcing

Need the current datasheet?

Send the module model, the roof layout and the country. We reply with the microinverter models on the compatibility list, plus gateway and trunk cable options.

Request a quote